Performance of the BGO endcap calorimeter with phototriode readout for the CMD-2 detector

The endcap calorimeter of the CMD-2 detector for the VEPP-2M collider is described. The calorimeter contains 680 BGO crystals read out by the vacuum phototriodes. Charge sensitive preamplifiers are placed directly on the phototriodes for the best noise performance. The calorimeter was installed duri...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Grigoriev, D.N., Akhmetshin, R.R., Beschastnov, P.M., Fedorenko, V.E., Pyata, E.E., Smakhtin, V.P., Yudin, Yu.V., Shlegel, V.N., Vasiliev, Y.V.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The endcap calorimeter of the CMD-2 detector for the VEPP-2M collider is described. The calorimeter contains 680 BGO crystals read out by the vacuum phototriodes. Charge sensitive preamplifiers are placed directly on the phototriodes for the best noise performance. The calorimeter was installed during the last year. Calibration by cosmic rays showed the energy equivalent of the electronic noise to be about 0.9 MeV during operation in a 1 T magnetic field which corresponds to design value.< >