A new control algorithm for three-phase PWM buck rectifier with input displacement factor compensation

A new control algorithm for the three-phase buck rectifier with an input filter is developed. The algorithm employs a separate control loop for compensation of the input current displacement factor in steady-state, in addition to the standard output voltage regulation loop. The algorithm allows sepa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Hiti, S., Vlatkovic, V., Borojevic, D., Lee, F.C.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A new control algorithm for the three-phase buck rectifier with an input filter is developed. The algorithm employs a separate control loop for compensation of the input current displacement factor in steady-state, in addition to the standard output voltage regulation loop. The algorithm allows separate design of the input filter and of closed loop output voltage control. The design procedure is explained and illustrated on an example. The algorithm is verified experimentally on an 1-kW, 100-kHz, three-phase isolated buck power converter.< >