A smart 2-D wind sensor with self-test function
A 2-D smart wind sensor with self-testing function was designed, fabricated and tested in this paper. It is composed of cross-structure heaters and four symmetrically located sensing parts. When the flow angle changes clockwise, the temperature differences among the four parts, namely T 13 (T 24 ) a...
Gespeichert in:
Hauptverfasser: | , , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A 2-D smart wind sensor with self-testing function was designed, fabricated and tested in this paper. It is composed of cross-structure heaters and four symmetrically located sensing parts. When the flow angle changes clockwise, the temperature differences among the four parts, namely T 13 (T 24 ) and T 12 (T 14 ) will be sine (cosine) functions of wind direction. Further study shows that the amplitudes of T 13 and T 24 are radic2 times of T 12 and T 14 , and the phases are 45 degree before the latter. Then two wind direction values can be obtained for self-test without additional components. In order to achieve moderate sensitivity without post-MEMS etching, thermal insulated substrate was introduced to fabricate calorimetric flow sensor instead of silicon wafer. The proposed sensor was fabricated on the low thermal conduction substrate Pyrex7740 using single lift-off process. Finally, wind tunnel test was carried out in constant power (CP) mode, and the test results show reasonable agreement with the simulation results. |
---|---|
ISSN: | 1930-0395 2168-9229 |
DOI: | 10.1109/ICSENS.2008.4716385 |