Synchronous rectified step-down converter susceptibility to conducted and radiated EMI
In this paper the susceptibility of synchronous rectified step-down converters to electromagnetic interference (100 kHz - 500 MHz) is examined and evaluated by experimental measurements. Performance degradation of linear low dropout regulators due to RF rectification and non-linear effects of RFI on...
Gespeichert in:
1. Verfasser: | |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this paper the susceptibility of synchronous rectified step-down converters to electromagnetic interference (100 kHz - 500 MHz) is examined and evaluated by experimental measurements. Performance degradation of linear low dropout regulators due to RF rectification and non-linear effects of RFI on error amplifiers is well documented. SR buck converters exhibit system stability and poor transient response behavior due to low-level RF injection and a complete circuit failure operation in presence of high-level RF injection. The use of L-C filter for RFI solution must be designed carefully as it can degrade the converterpsilas transient response. |
---|---|
ISSN: | 2158-110X 2158-1118 |
DOI: | 10.1109/ISEMC.2008.4652080 |