Measurement of current density vectors in a live pig for the study of human electro-muscular incapacitation devices
Current density imaging (CDI) is an MRI technique used to quantitatively measure current density vectors in biological tissue. A CDI sequence and corresponding experimental method were developed for the study of human electro-muscular incapacitation (HEMI) devices using an animal model. Measurements...
Gespeichert in:
Veröffentlicht in: | 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society 2008-01, Vol.2008, p.5842-5845 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Current density imaging (CDI) is an MRI technique used to quantitatively measure current density vectors in biological tissue. A CDI sequence and corresponding experimental method were developed for the study of human electro-muscular incapacitation (HEMI) devices using an animal model. Measurements of current density vectors were performed in piglets weighing 4 to 5 kg. Pathways of current density vectors in the region of the chest and heart were investigated using vector plotting and streamline integration methods. Measurement of current density vectors were also used to analyze the relationship between applied current amplitude and measured current density magnitude in the range of 10 mA to 45 mA of applied current. |
---|---|