Gas poisoning of 612-M and 311-XM cathodes

A 2 kA cathode was successfully developed for the DARHT-II injector [1]. Since the DARHT injector cannot be baked and there may be virtual leaks, the local pressure near the cathode was not ideal even though the system pressure was in the 10 -8 Torr range. In a series of experiments using quarter-in...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Kwan, J., Bieniosek, F., Henestroza, E., Leitner, M., Mitchell, R., Miram, G., Prichard, B., Scarpetti, R., Waldron, W., Westenskow, G.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A 2 kA cathode was successfully developed for the DARHT-II injector [1]. Since the DARHT injector cannot be baked and there may be virtual leaks, the local pressure near the cathode was not ideal even though the system pressure was in the 10 -8 Torr range. In a series of experiments using quarter-inch size button cathodes, we showed that gas poisoning was a significant factor in this pressure range. Furthermore we found that the 311-XM (doped with scandium and has an M coating) cathode was less affected by gas poisoning than the 612-M, corresponding to a lower effective work function. Water vapor was found to be the worst contaminant among the various gases that we have tested. With a 6.5rdquo diameter 311-XM cathode, the DARHT-II injector produced > 2 kA corresponding to a current density of 10 A/cm 2 .
DOI:10.1109/IVELEC.2008.4556407