A High Efficient Quality Control Strategy for Wavelet-Based ECG Data Compression System
Maintaining retrieved signal with desired quality is crucial for ECG data compression. In this paper, a high efficient quality control strategy is proposed for wavelet-based ECG data compression. The strategy is based on a modified non-linear quantization scheme that can obtain a linear distortion b...
Gespeichert in:
Hauptverfasser: | , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Maintaining retrieved signal with desired quality is crucial for ECG data compression. In this paper, a high efficient quality control strategy is proposed for wavelet-based ECG data compression. The strategy is based on a modified non-linear quantization scheme that can obtain a linear distortion behavior with respective to a control variable. The linear distortion characteristic supports the design of a linear control variable prediction algorithm. By using the MIT-BIH arrhythmia database, the experimental results show that the linear control variable prediction method can effectively improve the convergence speed than the previous literatures. |
---|---|
ISSN: | 1948-2914 1948-2922 |