Tracking organ overlap for a constrained non-rigid registration algorithm

This paper tracks organ (prostate, rectum, bladder) overlap in a constrained non-rigid registration (NRR) algorithm to register computed tomographic (CT) images used in external beam prostate radiotherapy. The local motion of the organs is described by a hierarchical multi-resolution FFD based on cu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Greene, W. H., Chelikani, S., Papademetris, X., Staib, L. H., Knisely, J. P. S., Duncan, J.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper tracks organ (prostate, rectum, bladder) overlap in a constrained non-rigid registration (NRR) algorithm to register computed tomographic (CT) images used in external beam prostate radiotherapy. The local motion of the organs is described by a hierarchical multi-resolution FFD based on cubic B-splines. Registration is achieved by minimizing a cost function which is a combination of three functions representing the overlap of the critical organs, image similarity and smoothness of the transformation. The constrained NRR algorithm generated better registration results when compared to an unconstrained NRR algorithm.
ISSN:1945-7928
1945-8452