Manipulation of Biological Samples using Electric Field

The paper presents original contributions at manipulation of biological samples using electric field (dielectrophoresis). Design considerations, fabrication processes and experimental results of three original three dimensional (3D) dielectrophoretic (DEP) structures: DEP chip with 3D silicon electr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Iliescu, C., Guo Lin Xu, Poh Lam Ong, Liming Yu, Tay, F.E.H., Iliescu, F.S., Tresset, G.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The paper presents original contributions at manipulation of biological samples using electric field (dielectrophoresis). Design considerations, fabrication processes and experimental results of three original three dimensional (3D) dielectrophoretic (DEP) structures: DEP chip with 3D silicon electrodes, DEP chip with 3D electric field gradient and 3D filtering chip are analyzed. The paper presents also the experimental results of trapping yeast cells.
ISSN:1545-827X
2377-0678
DOI:10.1109/SMICND.2007.4519649