CT Saturation Calculations - Are they Applicable in the Modern World? - Part II, Proposed Responsibilities

Part I expressed concerns about using IEEE Standard C37.110-1996 (1+X/R) criteria for sizing current transformers (CT's) for feeder short-circuit conditions [1]. Part II introduces an overview of relay filter algorithms, and proposes responsibilities of the IEEE Power System Relay Committee (PS...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Cosse, R.E., Dunn, D.G., Spiewak, R.M., Zocholl, S.E., Hazel, T., Rollay, D.T.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 11
container_issue
container_start_page 1
container_title
container_volume
creator Cosse, R.E.
Dunn, D.G.
Spiewak, R.M.
Zocholl, S.E.
Hazel, T.
Rollay, D.T.
description Part I expressed concerns about using IEEE Standard C37.110-1996 (1+X/R) criteria for sizing current transformers (CT's) for feeder short-circuit conditions [1]. Part II introduces an overview of relay filter algorithms, and proposes responsibilities of the IEEE Power System Relay Committee (PSRC), operating company and engineering company electrical power engineers, CT manufacturers, switchgear manufacturers, and relay manufacturers to guarantee CT/relay system performance. International Electrotechnical Commission (IEC) responsibilities are also included.
doi_str_mv 10.1109/PCICON.2007.4365788
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_4365788</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>4365788</ieee_id><sourcerecordid>4365788</sourcerecordid><originalsourceid>FETCH-LOGICAL-i90t-1ab5eee0b02ada8f97b0f47572ab565b8f5ff51946bbe99750419d80e93650dd3</originalsourceid><addsrcrecordid>eNotkMtOwzAURM1LopR-QTf-AFKuEzu2V6iKeEQqtIJKLCu7vhGuTBPZ6aJ_T4CuZjQzOoshZMpgxhjo-1VVV8u3WQ4gZ7wohVTqjNwwnnPOGAd1TkY5K1mmWC4vyERLdeoKrS_JCEBDVgiQ12SS0g4AmCw5CDEiu2pNP0x_iKb37Z5WJmwP4c8nmtF5RNp_4ZHOuy74rbEBqd__RvS1dRj39LONwT0M05WJPa3rO7qKbdcmdPQdUzdgvPXB9x7TLblqTEg4OemYrJ8e19VLtlg-19V8kXkNfcaMFYgIFnLjjGq0tNBwKWQ-FKWwqhFNI5jmpbWotRTAmXYKUA-_gHPFmEz_sX7AbLrov008bk6vFT9mzFxr</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>CT Saturation Calculations - Are they Applicable in the Modern World? - Part II, Proposed Responsibilities</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Cosse, R.E. ; Dunn, D.G. ; Spiewak, R.M. ; Zocholl, S.E. ; Hazel, T. ; Rollay, D.T.</creator><creatorcontrib>Cosse, R.E. ; Dunn, D.G. ; Spiewak, R.M. ; Zocholl, S.E. ; Hazel, T. ; Rollay, D.T.</creatorcontrib><description>Part I expressed concerns about using IEEE Standard C37.110-1996 (1+X/R) criteria for sizing current transformers (CT's) for feeder short-circuit conditions [1]. Part II introduces an overview of relay filter algorithms, and proposes responsibilities of the IEEE Power System Relay Committee (PSRC), operating company and engineering company electrical power engineers, CT manufacturers, switchgear manufacturers, and relay manufacturers to guarantee CT/relay system performance. International Electrotechnical Commission (IEC) responsibilities are also included.</description><identifier>ISSN: 0090-3507</identifier><identifier>ISBN: 9781424411399</identifier><identifier>ISBN: 1424411394</identifier><identifier>EISSN: 2161-8127</identifier><identifier>EISBN: 1424411408</identifier><identifier>EISBN: 9781424411405</identifier><identifier>DOI: 10.1109/PCICON.2007.4365788</identifier><language>eng</language><publisher>IEEE</publisher><subject>Analog-to-Digital (A/D) ; bipolar peak detector ; Circuit faults ; cosine filter ; Current transformers ; Digital Signal processing (DSP) ; Discrete Fourier Transform (DFT) ; Fault currents ; Filters ; Finite Impulse Response (FIR) filter ; IEC ; Infinite Impulse Response (IIR) ; Manufacturing ; MIMIC filter ; Power engineering and energy ; Power system relaying ; proprietary algorithms ; Root-Mean-Square (RMS) sampling ; sample and hold ; Switchgear ; System performance</subject><ispartof>2007 IEEE Petroleum and Chemical Industry Technical Conference, 2007, p.1-11</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/4365788$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,27902,54895</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/4365788$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Cosse, R.E.</creatorcontrib><creatorcontrib>Dunn, D.G.</creatorcontrib><creatorcontrib>Spiewak, R.M.</creatorcontrib><creatorcontrib>Zocholl, S.E.</creatorcontrib><creatorcontrib>Hazel, T.</creatorcontrib><creatorcontrib>Rollay, D.T.</creatorcontrib><title>CT Saturation Calculations - Are they Applicable in the Modern World? - Part II, Proposed Responsibilities</title><title>2007 IEEE Petroleum and Chemical Industry Technical Conference</title><addtitle>PCICON</addtitle><description>Part I expressed concerns about using IEEE Standard C37.110-1996 (1+X/R) criteria for sizing current transformers (CT's) for feeder short-circuit conditions [1]. Part II introduces an overview of relay filter algorithms, and proposes responsibilities of the IEEE Power System Relay Committee (PSRC), operating company and engineering company electrical power engineers, CT manufacturers, switchgear manufacturers, and relay manufacturers to guarantee CT/relay system performance. International Electrotechnical Commission (IEC) responsibilities are also included.</description><subject>Analog-to-Digital (A/D)</subject><subject>bipolar peak detector</subject><subject>Circuit faults</subject><subject>cosine filter</subject><subject>Current transformers</subject><subject>Digital Signal processing (DSP)</subject><subject>Discrete Fourier Transform (DFT)</subject><subject>Fault currents</subject><subject>Filters</subject><subject>Finite Impulse Response (FIR) filter</subject><subject>IEC</subject><subject>Infinite Impulse Response (IIR)</subject><subject>Manufacturing</subject><subject>MIMIC filter</subject><subject>Power engineering and energy</subject><subject>Power system relaying</subject><subject>proprietary algorithms</subject><subject>Root-Mean-Square (RMS) sampling</subject><subject>sample and hold</subject><subject>Switchgear</subject><subject>System performance</subject><issn>0090-3507</issn><issn>2161-8127</issn><isbn>9781424411399</isbn><isbn>1424411394</isbn><isbn>1424411408</isbn><isbn>9781424411405</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>2007</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotkMtOwzAURM1LopR-QTf-AFKuEzu2V6iKeEQqtIJKLCu7vhGuTBPZ6aJ_T4CuZjQzOoshZMpgxhjo-1VVV8u3WQ4gZ7wohVTqjNwwnnPOGAd1TkY5K1mmWC4vyERLdeoKrS_JCEBDVgiQ12SS0g4AmCw5CDEiu2pNP0x_iKb37Z5WJmwP4c8nmtF5RNp_4ZHOuy74rbEBqd__RvS1dRj39LONwT0M05WJPa3rO7qKbdcmdPQdUzdgvPXB9x7TLblqTEg4OemYrJ8e19VLtlg-19V8kXkNfcaMFYgIFnLjjGq0tNBwKWQ-FKWwqhFNI5jmpbWotRTAmXYKUA-_gHPFmEz_sX7AbLrov008bk6vFT9mzFxr</recordid><startdate>200709</startdate><enddate>200709</enddate><creator>Cosse, R.E.</creator><creator>Dunn, D.G.</creator><creator>Spiewak, R.M.</creator><creator>Zocholl, S.E.</creator><creator>Hazel, T.</creator><creator>Rollay, D.T.</creator><general>IEEE</general><scope>6IE</scope><scope>6IH</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIO</scope></search><sort><creationdate>200709</creationdate><title>CT Saturation Calculations - Are they Applicable in the Modern World? - Part II, Proposed Responsibilities</title><author>Cosse, R.E. ; Dunn, D.G. ; Spiewak, R.M. ; Zocholl, S.E. ; Hazel, T. ; Rollay, D.T.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i90t-1ab5eee0b02ada8f97b0f47572ab565b8f5ff51946bbe99750419d80e93650dd3</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Analog-to-Digital (A/D)</topic><topic>bipolar peak detector</topic><topic>Circuit faults</topic><topic>cosine filter</topic><topic>Current transformers</topic><topic>Digital Signal processing (DSP)</topic><topic>Discrete Fourier Transform (DFT)</topic><topic>Fault currents</topic><topic>Filters</topic><topic>Finite Impulse Response (FIR) filter</topic><topic>IEC</topic><topic>Infinite Impulse Response (IIR)</topic><topic>Manufacturing</topic><topic>MIMIC filter</topic><topic>Power engineering and energy</topic><topic>Power system relaying</topic><topic>proprietary algorithms</topic><topic>Root-Mean-Square (RMS) sampling</topic><topic>sample and hold</topic><topic>Switchgear</topic><topic>System performance</topic><toplevel>online_resources</toplevel><creatorcontrib>Cosse, R.E.</creatorcontrib><creatorcontrib>Dunn, D.G.</creatorcontrib><creatorcontrib>Spiewak, R.M.</creatorcontrib><creatorcontrib>Zocholl, S.E.</creatorcontrib><creatorcontrib>Hazel, T.</creatorcontrib><creatorcontrib>Rollay, D.T.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan (POP) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE</collection><collection>IEEE Proceedings Order Plans (POP) 1998-present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Cosse, R.E.</au><au>Dunn, D.G.</au><au>Spiewak, R.M.</au><au>Zocholl, S.E.</au><au>Hazel, T.</au><au>Rollay, D.T.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>CT Saturation Calculations - Are they Applicable in the Modern World? - Part II, Proposed Responsibilities</atitle><btitle>2007 IEEE Petroleum and Chemical Industry Technical Conference</btitle><stitle>PCICON</stitle><date>2007-09</date><risdate>2007</risdate><spage>1</spage><epage>11</epage><pages>1-11</pages><issn>0090-3507</issn><eissn>2161-8127</eissn><isbn>9781424411399</isbn><isbn>1424411394</isbn><eisbn>1424411408</eisbn><eisbn>9781424411405</eisbn><abstract>Part I expressed concerns about using IEEE Standard C37.110-1996 (1+X/R) criteria for sizing current transformers (CT's) for feeder short-circuit conditions [1]. Part II introduces an overview of relay filter algorithms, and proposes responsibilities of the IEEE Power System Relay Committee (PSRC), operating company and engineering company electrical power engineers, CT manufacturers, switchgear manufacturers, and relay manufacturers to guarantee CT/relay system performance. International Electrotechnical Commission (IEC) responsibilities are also included.</abstract><pub>IEEE</pub><doi>10.1109/PCICON.2007.4365788</doi><tpages>11</tpages></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 0090-3507
ispartof 2007 IEEE Petroleum and Chemical Industry Technical Conference, 2007, p.1-11
issn 0090-3507
2161-8127
language eng
recordid cdi_ieee_primary_4365788
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Analog-to-Digital (A/D)
bipolar peak detector
Circuit faults
cosine filter
Current transformers
Digital Signal processing (DSP)
Discrete Fourier Transform (DFT)
Fault currents
Filters
Finite Impulse Response (FIR) filter
IEC
Infinite Impulse Response (IIR)
Manufacturing
MIMIC filter
Power engineering and energy
Power system relaying
proprietary algorithms
Root-Mean-Square (RMS) sampling
sample and hold
Switchgear
System performance
title CT Saturation Calculations - Are they Applicable in the Modern World? - Part II, Proposed Responsibilities
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-11T18%3A18%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=CT%20Saturation%20Calculations%20-%20Are%20they%20Applicable%20in%20the%20Modern%20World?%20-%20Part%20II,%20Proposed%20Responsibilities&rft.btitle=2007%20IEEE%20Petroleum%20and%20Chemical%20Industry%20Technical%20Conference&rft.au=Cosse,%20R.E.&rft.date=2007-09&rft.spage=1&rft.epage=11&rft.pages=1-11&rft.issn=0090-3507&rft.eissn=2161-8127&rft.isbn=9781424411399&rft.isbn_list=1424411394&rft_id=info:doi/10.1109/PCICON.2007.4365788&rft_dat=%3Cieee_6IE%3E4365788%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&rft.eisbn=1424411408&rft.eisbn_list=9781424411405&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=4365788&rfr_iscdi=true