The Stanford Superconducting Recyclotron

With four orbits of recirculation, the HEPL superconducting recyclotron is expected to provide a high duty factor (> 70%) electron beam at 300 MeV by 1982. At present the beam has been recirculated twice and extracted. To date, maximum energy has been 156 MeV with best energy resolution (FWHM) 0....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on nuclear science 1979-01, Vol.26 (3), p.3246-3248
Hauptverfasser: Lyneis, Claude M., McAshan, Michael S., Rand, Roy E., Schwettman, H. Alan, Smith, Todd I., Turneaure, John P.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:With four orbits of recirculation, the HEPL superconducting recyclotron is expected to provide a high duty factor (> 70%) electron beam at 300 MeV by 1982. At present the beam has been recirculated twice and extracted. To date, maximum energy has been 156 MeV with best energy resolution (FWHM) 0.018%. The dependence of beam breakup starting currents on orbit optics has been investigated. Installation of the components for the third and fourth orbits will be completed this year.
ISSN:0018-9499
1558-1578
DOI:10.1109/TNS.1979.4329998