X-Ray Photoemission Calculations

Results are presented from an extensive parametric study of x-ray photoemission. Calculations were performed of fore and back emission yield and energy-angular distribution, including the two-dimensional, asymmetric angular distribution for non-normal photon incidence, for a broad range of photon en...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on nuclear science 1975-01, Vol.22 (6), p.2345-2350
Hauptverfasser: Chadsey, William L., Wilson, C. Woodrow, Pine, Vernon W.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Results are presented from an extensive parametric study of x-ray photoemission. Calculations were performed of fore and back emission yield and energy-angular distribution, including the two-dimensional, asymmetric angular distribution for non-normal photon incidence, for a broad range of photon energies, angles of incidence, and material atomic numbers. Monte Carlo and analytical calculations are compared with one another and with experimental data. A new Monte Carlo method is presented which makes feasible the calculation of the two-dimensional angular distribution and yields a continuous representation of the distribution in functional form.
ISSN:0018-9499
1558-1578
DOI:10.1109/TNS.1975.4328131