Transverse Beam Motion in the Fermilab Booster Accelerator

Measurements are presented of the transverse properties of the booster synchrotron. The principal transverse limitations to operational performance have been due to restricted aperture and improper multiturn injection. In addition to these features, working point, chromaticities, high-intensity effe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on nuclear science 1975-01, Vol.22 (3), p.1900-1903
Hauptverfasser: Gray, E. R., Hubbard, E. L., Mills, F. E., Owen, C. W., Peters, R. E., Ruggiero, A. G., Shea, M. F.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Measurements are presented of the transverse properties of the booster synchrotron. The principal transverse limitations to operational performance have been due to restricted aperture and improper multiturn injection. In addition to these features, working point, chromaticities, high-intensity effects, and injection matching are discussed.
ISSN:0018-9499
1558-1578