The Calibration and Stability of a 1200°F Permanent Magnet In-Core Sodium Flowmeter

A previously described, permanent magnet (PM), in-core flowmeter for use in sodium cooled reactors has been fabricated and installed in the Argonne National Laboratory (ANL) Sodium Flowmeter Calibration Loop. The calibration test facility and procedures are described and a typical family of flowmete...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on nuclear science 1968-02, Vol.15 (1), p.37-40
Hauptverfasser: Glass, M. C., Popper, G. F.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A previously described, permanent magnet (PM), in-core flowmeter for use in sodium cooled reactors has been fabricated and installed in the Argonne National Laboratory (ANL) Sodium Flowmeter Calibration Loop. The calibration test facility and procedures are described and a typical family of flowmeter calibration curves are presented. The measured sensitivity is compared to that theoretically predicted and the discrepancies are discussed. Long term performance of the flowmeter is discussed.