Analysis of Three Phase Self-Excited Induction Generator Under Static and Dynamic Loads

This paper proposes a scheme for a steady state analysis of a three phase self-excited induction generator feeding both static and dynamic loads. The proposed scheme to solve for the unknowns is a sequential numerical optimizer. This optimizer consists of two parts based on genetic algorithm (GA) is...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Alolah, A.I., Alkanhal, M.A.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper proposes a scheme for a steady state analysis of a three phase self-excited induction generator feeding both static and dynamic loads. The proposed scheme to solve for the unknowns is a sequential numerical optimizer. This optimizer consists of two parts based on genetic algorithm (GA) is used to bring the values of the unknowns close to the region of the (optimality) solution Unlike the other reported methods of analysis, the same equation is to be solved irrespective of the unknown parameters.
DOI:10.1109/IEMDC.2007.383700