Abrupt Power-Off Detector for Mobile TFT-LCD Driver IC
A circuit technique to detect unexpected power condition such as battery separation is presented. Abrupt power-off due to this unexpected power condition may cause an abnormal display in mobile TFT-LCD because adequate power-off sequence cannot be performed. To demonstrate feasibility of the APD, te...
Gespeichert in:
Hauptverfasser: | , , , , , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A circuit technique to detect unexpected power condition such as battery separation is presented. Abrupt power-off due to this unexpected power condition may cause an abnormal display in mobile TFT-LCD because adequate power-off sequence cannot be performed. To demonstrate feasibility of the APD, test chip was designed and fabricated in a 30-V/4-um 5-V/0.8-um 2.5-V/0.25-um triple-well CMOS process. Experimental results show that the proposed APD improves display quality by allowing a proper power-off sequence at all abrupt power-off conditions. |
---|---|