Operation of High-Power Cycloconverter-Fed Gearless Drives Under Abnormal Conditions
This paper presents the behavior of large power mills (more than 10 MW each) that are fed by cycloconverters. Special attention is dedicated to the protection philosophy to avoid operational interruptions that can produce huge production losses and equipment damage. Several failure possibilities are...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on industry applications 2007-05, Vol.43 (3), p.814-820 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper presents the behavior of large power mills (more than 10 MW each) that are fed by cycloconverters. Special attention is dedicated to the protection philosophy to avoid operational interruptions that can produce huge production losses and equipment damage. Several failure possibilities are considered: control failure, complete power outage, if a thyristor fails and cannot block reverse voltage, etc. Simulation studies and field measurements show that large currents and torque can occur under certain circumstances and that motor foundations must be able to support them. As a general conclusion, it can be said that proper protective design effectively avoids equipment damage |
---|---|