Enhancement of lung nodules through stereo image processing

The lack of sensitivity of chest radiographs to cancer nodules of the lung is in part due to lung parenchyma and bone obscuring nodule features. A stereo image processing technique, the cut-plane procedure, is designed to eliminate voxels in planes perpendicular to the line of sight. However, this p...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Frye, R.E., Ledley, R.S.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 709 vol.1
container_issue
container_start_page 708
container_title
container_volume 1
creator Frye, R.E.
Ledley, R.S.
description The lack of sensitivity of chest radiographs to cancer nodules of the lung is in part due to lung parenchyma and bone obscuring nodule features. A stereo image processing technique, the cut-plane procedure, is designed to eliminate voxels in planes perpendicular to the line of sight. However, this procedure does not perform adequately when applied to medical images. The authors present some modifications which improve the performance of this procedure; examples are shown.< >
doi_str_mv 10.1109/IEMBS.1994.412178
format Conference Proceeding
fullrecord <record><control><sourceid>ieee_6IE</sourceid><recordid>TN_cdi_ieee_primary_412178</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>412178</ieee_id><sourcerecordid>412178</sourcerecordid><originalsourceid>FETCH-LOGICAL-i104t-55c52553d529dcc5b855ec7972e639c268d89bb31c78c11a70e42a21d66c0aa33</originalsourceid><addsrcrecordid>eNotj1FLwzAUhQMiKLM_QJ_yB1pzk94mwScdVQcTH9yeR5retZUuHU374L-3sB0OfG-H7zD2CCIDEPZ5U369_WRgbZ7lIEGbG5ZYbcRSJQUKvGNJjL9iCUotlb5nL2VoXfB0ojDx4cj7OTQ8DPXcU-RTOw5z0_I40UgD706uIX4eB08xdqF5YLdH10dKrlyx_Xu5W3-m2--Pzfp1m3Yg8ilF9CgRVY3S1t5jZRDJa6slFcp6WZja2KpS4LXxAE4LyqWTUBeFF84ptWJPl92OiA7ncfEY_w6Xh-ofyaBGRA</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>conference_proceeding</recordtype></control><display><type>conference_proceeding</type><title>Enhancement of lung nodules through stereo image processing</title><source>IEEE Electronic Library (IEL) Conference Proceedings</source><creator>Frye, R.E. ; Ledley, R.S.</creator><creatorcontrib>Frye, R.E. ; Ledley, R.S.</creatorcontrib><description>The lack of sensitivity of chest radiographs to cancer nodules of the lung is in part due to lung parenchyma and bone obscuring nodule features. A stereo image processing technique, the cut-plane procedure, is designed to eliminate voxels in planes perpendicular to the line of sight. However, this procedure does not perform adequately when applied to medical images. The authors present some modifications which improve the performance of this procedure; examples are shown.&lt; &gt;</description><identifier>ISBN: 9780780320505</identifier><identifier>ISBN: 0780320506</identifier><identifier>DOI: 10.1109/IEMBS.1994.412178</identifier><language>eng</language><publisher>IEEE</publisher><subject>Biomedical imaging ; Bones ; Cancer ; Diagnostic radiography ; Lungs ; Stereo vision</subject><ispartof>Proceedings of 16th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 1994, Vol.1, p.708-709 vol.1</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/412178$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>309,310,776,780,785,786,2052,4036,4037,27902,54895</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/412178$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Frye, R.E.</creatorcontrib><creatorcontrib>Ledley, R.S.</creatorcontrib><title>Enhancement of lung nodules through stereo image processing</title><title>Proceedings of 16th Annual International Conference of the IEEE Engineering in Medicine and Biology Society</title><addtitle>IEMBS</addtitle><description>The lack of sensitivity of chest radiographs to cancer nodules of the lung is in part due to lung parenchyma and bone obscuring nodule features. A stereo image processing technique, the cut-plane procedure, is designed to eliminate voxels in planes perpendicular to the line of sight. However, this procedure does not perform adequately when applied to medical images. The authors present some modifications which improve the performance of this procedure; examples are shown.&lt; &gt;</description><subject>Biomedical imaging</subject><subject>Bones</subject><subject>Cancer</subject><subject>Diagnostic radiography</subject><subject>Lungs</subject><subject>Stereo vision</subject><isbn>9780780320505</isbn><isbn>0780320506</isbn><fulltext>true</fulltext><rsrctype>conference_proceeding</rsrctype><creationdate>1994</creationdate><recordtype>conference_proceeding</recordtype><sourceid>6IE</sourceid><sourceid>RIE</sourceid><recordid>eNotj1FLwzAUhQMiKLM_QJ_yB1pzk94mwScdVQcTH9yeR5retZUuHU374L-3sB0OfG-H7zD2CCIDEPZ5U369_WRgbZ7lIEGbG5ZYbcRSJQUKvGNJjL9iCUotlb5nL2VoXfB0ojDx4cj7OTQ8DPXcU-RTOw5z0_I40UgD706uIX4eB08xdqF5YLdH10dKrlyx_Xu5W3-m2--Pzfp1m3Yg8ilF9CgRVY3S1t5jZRDJa6slFcp6WZja2KpS4LXxAE4LyqWTUBeFF84ptWJPl92OiA7ncfEY_w6Xh-ofyaBGRA</recordid><startdate>1994</startdate><enddate>1994</enddate><creator>Frye, R.E.</creator><creator>Ledley, R.S.</creator><general>IEEE</general><scope>6IE</scope><scope>6IL</scope><scope>CBEJK</scope><scope>RIE</scope><scope>RIL</scope></search><sort><creationdate>1994</creationdate><title>Enhancement of lung nodules through stereo image processing</title><author>Frye, R.E. ; Ledley, R.S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-i104t-55c52553d529dcc5b855ec7972e639c268d89bb31c78c11a70e42a21d66c0aa33</frbrgroupid><rsrctype>conference_proceedings</rsrctype><prefilter>conference_proceedings</prefilter><language>eng</language><creationdate>1994</creationdate><topic>Biomedical imaging</topic><topic>Bones</topic><topic>Cancer</topic><topic>Diagnostic radiography</topic><topic>Lungs</topic><topic>Stereo vision</topic><toplevel>online_resources</toplevel><creatorcontrib>Frye, R.E.</creatorcontrib><creatorcontrib>Ledley, R.S.</creatorcontrib><collection>IEEE Electronic Library (IEL) Conference Proceedings</collection><collection>IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume</collection><collection>IEEE Xplore All Conference Proceedings</collection><collection>IEEE Electronic Library (IEL)</collection><collection>IEEE Proceedings Order Plans (POP All) 1998-Present</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Frye, R.E.</au><au>Ledley, R.S.</au><format>book</format><genre>proceeding</genre><ristype>CONF</ristype><atitle>Enhancement of lung nodules through stereo image processing</atitle><btitle>Proceedings of 16th Annual International Conference of the IEEE Engineering in Medicine and Biology Society</btitle><stitle>IEMBS</stitle><date>1994</date><risdate>1994</risdate><volume>1</volume><spage>708</spage><epage>709 vol.1</epage><pages>708-709 vol.1</pages><isbn>9780780320505</isbn><isbn>0780320506</isbn><abstract>The lack of sensitivity of chest radiographs to cancer nodules of the lung is in part due to lung parenchyma and bone obscuring nodule features. A stereo image processing technique, the cut-plane procedure, is designed to eliminate voxels in planes perpendicular to the line of sight. However, this procedure does not perform adequately when applied to medical images. The authors present some modifications which improve the performance of this procedure; examples are shown.&lt; &gt;</abstract><pub>IEEE</pub><doi>10.1109/IEMBS.1994.412178</doi></addata></record>
fulltext fulltext_linktorsrc
identifier ISBN: 9780780320505
ispartof Proceedings of 16th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 1994, Vol.1, p.708-709 vol.1
issn
language eng
recordid cdi_ieee_primary_412178
source IEEE Electronic Library (IEL) Conference Proceedings
subjects Biomedical imaging
Bones
Cancer
Diagnostic radiography
Lungs
Stereo vision
title Enhancement of lung nodules through stereo image processing
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-05T18%3A26%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ieee_6IE&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=proceeding&rft.atitle=Enhancement%20of%20lung%20nodules%20through%20stereo%20image%20processing&rft.btitle=Proceedings%20of%2016th%20Annual%20International%20Conference%20of%20the%20IEEE%20Engineering%20in%20Medicine%20and%20Biology%20Society&rft.au=Frye,%20R.E.&rft.date=1994&rft.volume=1&rft.spage=708&rft.epage=709%20vol.1&rft.pages=708-709%20vol.1&rft.isbn=9780780320505&rft.isbn_list=0780320506&rft_id=info:doi/10.1109/IEMBS.1994.412178&rft_dat=%3Cieee_6IE%3E412178%3C/ieee_6IE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=412178&rfr_iscdi=true