Binary vs decade inductive voltage divider comparison and error decomposition
An automatic inductive voltage divider (IVD) characterization method that can measure linearity by comparing IVDs with different structures is suggested. Structural models are employed to decompose an error vector into components that represent each divider. Initial tests at 400 Hz show that it is p...
Gespeichert in:
Hauptverfasser: | , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | An automatic inductive voltage divider (IVD) characterization method that can measure linearity by comparing IVDs with different structures is suggested. Structural models are employed to decompose an error vector into components that represent each divider. Initial tests at 400 Hz show that it is possible to separate errors due to binary and decade structures with a 2/spl sigma/ uncertainty of 0.05 parts per million (ppm).< > |
---|---|