Magnetic inclination measurement and signal transmission system for trench wall constructions

A NdFeB permanent magnet pendulum varies the output voltage of a semiconductor Hall-effect potentiometer. The angle dependent dc-voltage is converted into a signal of variable frequency (2-15 kHz). The angle sensors, the electronic circuits, and batteries are mounted in water-proof (20 bar) and shoc...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE Transactions on Magnetics (Institute of Electrical and Electronics Engineers); (United States) 1994-11, Vol.30 (6), p.4581-4583
Hauptverfasser: Vorlicek, K., Hauser, H., Franz, M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A NdFeB permanent magnet pendulum varies the output voltage of a semiconductor Hall-effect potentiometer. The angle dependent dc-voltage is converted into a signal of variable frequency (2-15 kHz). The angle sensors, the electronic circuits, and batteries are mounted in water-proof (20 bar) and shock protected (100 g) cases on the gripper. It is operated by two steel cables which are used for the signal transmission by enclosing ring-core transformers of high initial permeability. The received angular information is decoded by a microprocessor and displayed together with the excavation depth on a screen in the operation cabin of the excavator. The measurement system provides an angular resolution of 5.10/sup -3/ degrees and an absolute accuracy of 7.10/sup -3/ degrees at /spl plusmn/2 degrees total range.< >
ISSN:0018-9464
1941-0069
DOI:10.1109/20.334155