The focusing of surface-acoustic-waves launched from a slanted chirped transducer. I. Isotropic substrate

The focusing behavior of surface acoustic waves launched from a slanted chirped transducer (SCT) is explored using both a continuum model and a discrete model for sources associated with a linear FM chirp transducer on a substrate with isotropic properties. The continuum model leads to the predictio...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control ferroelectrics, and frequency control, 1989-09, Vol.36 (5), p.565-573
Hauptverfasser: Barnard, M.E., Lancaster, M.J., Paige, E.G.S.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The focusing behavior of surface acoustic waves launched from a slanted chirped transducer (SCT) is explored using both a continuum model and a discrete model for sources associated with a linear FM chirp transducer on a substrate with isotropic properties. The continuum model leads to the prediction of an understanding of effects that would arise in the radiation field of an SCT on an isotropic substrate. It is based on a representation of the transducer as a continuum of sources, with the radiation field determined by applying the stationary phase method, and is presented for infinitesimally short fingers. It is compared with a more direct and exact but less revealing method of determining the field based on a discrete array of sources. The effects of increasing finger lengths are considered. The results are related to the focusing of radiation by a lens.< >
ISSN:0885-3010
1525-8955
DOI:10.1109/58.31802