NSLS X-ray system RF system upgrade
Presently (Dec. 1992) three RF systems power the electron beam at the NSLS X-ray storage ring to 250 mA at 2.58 GeV. A fourth RF cavity and system is being installed to increase the machine reliability over pre-shutdown operational conditions (3 cavities). It also permits new levels of beam intensit...
Gespeichert in:
Hauptverfasser: | , , , , , , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Presently (Dec. 1992) three RF systems power the electron beam at the NSLS X-ray storage ring to 250 mA at 2.58 GeV. A fourth RF cavity and system is being installed to increase the machine reliability over pre-shutdown operational conditions (3 cavities). It also permits new levels of beam intensity and energy to be achieved in the X-ray ring. Intensities of 500 mA at 2.5 GeV as well as 250 mA at 2.8 GeV are anticipated. A description of the hardware, the installation and the modes of operation will be outlined in this paper. X-ray ring operations are scheduled to resume January 1993. Injection performance and high energy reliability will also be discussed.< > |
---|---|
DOI: | 10.1109/PAC.1993.309055 |