Sneak circuit path within a DPDT relay
A failed resistor in an electronic circuit was found to have been subjected to an overvoltage condition. One side of the resistor was connected to a dual-coil DPDT latching relay, and the other side to ground. The cause of this failure was found to be due to a threefold problem: 1. A test set that,...
Gespeichert in:
Hauptverfasser: | , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A failed resistor in an electronic circuit was found to have been subjected to an overvoltage condition. One side of the resistor was connected to a dual-coil DPDT latching relay, and the other side to ground. The cause of this failure was found to be due to a threefold problem: 1. A test set that, when powered on, would send simultaneous commands to both relay coils. 2. A sneak path through the relay when both relay coils were simultaneously energized. 3. A design that did not consider this sneak path.< > |
---|---|