The Culham Laboratory hypervelocity test facility

Culham Laboratory has designed and constructed a hypervelocity test facility (HTF) using electromagnetic launcher technology. Aimed at launching projectiles of approximately 1 gm to a velocity approaching 15 km/s, the facility is configured around an existing 1.1-MJ, 8-kV capacitor bank. The authors...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on magnetics 1989-01, Vol.25 (1), p.290-294
Hauptverfasser: Kear, M.J., Oxley, C.M., Burden, R.A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Culham Laboratory has designed and constructed a hypervelocity test facility (HTF) using electromagnetic launcher technology. Aimed at launching projectiles of approximately 1 gm to a velocity approaching 15 km/s, the facility is configured around an existing 1.1-MJ, 8-kV capacitor bank. The authors describe the electromagnetic launcher design and its power supply system and also report on its early operation. Theoretical performance is predicted and compared with experimental performance. A preliminary assessment of structural integrity, including rail and insulator damage, is presented.< >
ISSN:0018-9464
1941-0069
DOI:10.1109/20.22552