3-D measurement of thermal deformations on an ultra-high density circuit module with a laser range probe
A laser triangulation range sensor mounted on a coordinate measuring machine was used to measure thermally induced deformations in a circuit module. The module was housed in an environmental test chamber with optical access for the laser probe and measurements were made over a 25-125 degrees C range...
Gespeichert in:
Hauptverfasser: | , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A laser triangulation range sensor mounted on a coordinate measuring machine was used to measure thermally induced deformations in a circuit module. The module was housed in an environmental test chamber with optical access for the laser probe and measurements were made over a 25-125 degrees C range with an estimated accuracy of +or-5 mu m. The results show relative 3-D displacements of circuit module components which could cause failure of the module under thermal stress.< > |
---|---|
DOI: | 10.1109/ITHERM.1992.187757 |