20-element HgI/sub 2/ energy dispersive X-ray array detector system
Recent progress in the development of HgI/sub 2/ energy dispersive X-ray detector arrays and associated miniaturized processing electronics for synchrotron radiation research applications is described. The experimental results with a 20-element array detector were obtained under realistic synchrotro...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on nuclear science 1992-10, Vol.39 (5), p.1275-1280 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1280 |
---|---|
container_issue | 5 |
container_start_page | 1275 |
container_title | IEEE transactions on nuclear science |
container_volume | 39 |
creator | Iwanczyk, J.S. Dorri, N. Wang, M. Szczebiot, R.W. Dabrowski, A.J. Hedman, B. Hodgson, K.O. Patt, B.E. |
description | Recent progress in the development of HgI/sub 2/ energy dispersive X-ray detector arrays and associated miniaturized processing electronics for synchrotron radiation research applications is described. The experimental results with a 20-element array detector were obtained under realistic synchrotron beam conditions at SSRL. An energy resolution of 250 eV at 5.9 keV was achieved. Energy resolution and throughput measurements versus input count rate and energy of the incoming radiation have been measured. Extended X-ray absorption fine structure spectra were taken from diluted samples simulating proteins with nickel.< > |
doi_str_mv | 10.1109/23.173190 |
format | Article |
fullrecord | <record><control><sourceid>crossref_RIE</sourceid><recordid>TN_cdi_ieee_primary_173190</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ieee_id>173190</ieee_id><sourcerecordid>10_1109_23_173190</sourcerecordid><originalsourceid>FETCH-LOGICAL-c930-e6ddd546555a2f153e8b702cc9fb83d81eb40bd41ebabc6d40627a8879054a593</originalsourceid><addsrcrecordid>eNpFjztLxEAUhQdRMK4WtlbTWsxmXjeZKSWou7Bgs4VdmMfNEtkXM1HIvzdLBJt7uJyPcziEPAq-FILbUqqlqJWw_IoUAsAwAbW5JgXnwjCrrb0ldzl_Ta8GDgVpJGe4xwMeB7rarcv87aksKR4x7UYa-3zGlPsfpJ8suZG6dLkRBwzDKdE85gEP9-Smc_uMD3-6INu3122zYpuP93XzsmHBqqmlijGCrgDAyU6AQuNrLkOwnTcqGoFecx_1pM6HKmpeydoZU1sO2oFVC_I8x4Z0yjlh155Tf3BpbAVvL-Nbqdp5_MQ-zWyPiP_cbP4C1PtTKQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>20-element HgI/sub 2/ energy dispersive X-ray array detector system</title><source>IEEE Electronic Library Online</source><creator>Iwanczyk, J.S. ; Dorri, N. ; Wang, M. ; Szczebiot, R.W. ; Dabrowski, A.J. ; Hedman, B. ; Hodgson, K.O. ; Patt, B.E.</creator><creatorcontrib>Iwanczyk, J.S. ; Dorri, N. ; Wang, M. ; Szczebiot, R.W. ; Dabrowski, A.J. ; Hedman, B. ; Hodgson, K.O. ; Patt, B.E.</creatorcontrib><description>Recent progress in the development of HgI/sub 2/ energy dispersive X-ray detector arrays and associated miniaturized processing electronics for synchrotron radiation research applications is described. The experimental results with a 20-element array detector were obtained under realistic synchrotron beam conditions at SSRL. An energy resolution of 250 eV at 5.9 keV was achieved. Energy resolution and throughput measurements versus input count rate and energy of the incoming radiation have been measured. Extended X-ray absorption fine structure spectra were taken from diluted samples simulating proteins with nickel.< ></description><identifier>ISSN: 0018-9499</identifier><identifier>EISSN: 1558-1578</identifier><identifier>DOI: 10.1109/23.173190</identifier><identifier>CODEN: IETNAE</identifier><language>eng</language><publisher>IEEE</publisher><subject>Dispersion ; Electromagnetic wave absorption ; Energy measurement ; Energy resolution ; Nickel ; Proteins ; Sensor arrays ; Synchrotron radiation ; Throughput ; X-ray detectors</subject><ispartof>IEEE transactions on nuclear science, 1992-10, Vol.39 (5), p.1275-1280</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c930-e6ddd546555a2f153e8b702cc9fb83d81eb40bd41ebabc6d40627a8879054a593</citedby><cites>FETCH-LOGICAL-c930-e6ddd546555a2f153e8b702cc9fb83d81eb40bd41ebabc6d40627a8879054a593</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://ieeexplore.ieee.org/document/173190$$EHTML$$P50$$Gieee$$H</linktohtml><link.rule.ids>314,780,784,796,27924,27925,54758</link.rule.ids><linktorsrc>$$Uhttps://ieeexplore.ieee.org/document/173190$$EView_record_in_IEEE$$FView_record_in_$$GIEEE</linktorsrc></links><search><creatorcontrib>Iwanczyk, J.S.</creatorcontrib><creatorcontrib>Dorri, N.</creatorcontrib><creatorcontrib>Wang, M.</creatorcontrib><creatorcontrib>Szczebiot, R.W.</creatorcontrib><creatorcontrib>Dabrowski, A.J.</creatorcontrib><creatorcontrib>Hedman, B.</creatorcontrib><creatorcontrib>Hodgson, K.O.</creatorcontrib><creatorcontrib>Patt, B.E.</creatorcontrib><title>20-element HgI/sub 2/ energy dispersive X-ray array detector system</title><title>IEEE transactions on nuclear science</title><addtitle>TNS</addtitle><description>Recent progress in the development of HgI/sub 2/ energy dispersive X-ray detector arrays and associated miniaturized processing electronics for synchrotron radiation research applications is described. The experimental results with a 20-element array detector were obtained under realistic synchrotron beam conditions at SSRL. An energy resolution of 250 eV at 5.9 keV was achieved. Energy resolution and throughput measurements versus input count rate and energy of the incoming radiation have been measured. Extended X-ray absorption fine structure spectra were taken from diluted samples simulating proteins with nickel.< ></description><subject>Dispersion</subject><subject>Electromagnetic wave absorption</subject><subject>Energy measurement</subject><subject>Energy resolution</subject><subject>Nickel</subject><subject>Proteins</subject><subject>Sensor arrays</subject><subject>Synchrotron radiation</subject><subject>Throughput</subject><subject>X-ray detectors</subject><issn>0018-9499</issn><issn>1558-1578</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1992</creationdate><recordtype>article</recordtype><recordid>eNpFjztLxEAUhQdRMK4WtlbTWsxmXjeZKSWou7Bgs4VdmMfNEtkXM1HIvzdLBJt7uJyPcziEPAq-FILbUqqlqJWw_IoUAsAwAbW5JgXnwjCrrb0ldzl_Ta8GDgVpJGe4xwMeB7rarcv87aksKR4x7UYa-3zGlPsfpJ8suZG6dLkRBwzDKdE85gEP9-Smc_uMD3-6INu3122zYpuP93XzsmHBqqmlijGCrgDAyU6AQuNrLkOwnTcqGoFecx_1pM6HKmpeydoZU1sO2oFVC_I8x4Z0yjlh155Tf3BpbAVvL-Nbqdp5_MQ-zWyPiP_cbP4C1PtTKQ</recordid><startdate>199210</startdate><enddate>199210</enddate><creator>Iwanczyk, J.S.</creator><creator>Dorri, N.</creator><creator>Wang, M.</creator><creator>Szczebiot, R.W.</creator><creator>Dabrowski, A.J.</creator><creator>Hedman, B.</creator><creator>Hodgson, K.O.</creator><creator>Patt, B.E.</creator><general>IEEE</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>199210</creationdate><title>20-element HgI/sub 2/ energy dispersive X-ray array detector system</title><author>Iwanczyk, J.S. ; Dorri, N. ; Wang, M. ; Szczebiot, R.W. ; Dabrowski, A.J. ; Hedman, B. ; Hodgson, K.O. ; Patt, B.E.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c930-e6ddd546555a2f153e8b702cc9fb83d81eb40bd41ebabc6d40627a8879054a593</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1992</creationdate><topic>Dispersion</topic><topic>Electromagnetic wave absorption</topic><topic>Energy measurement</topic><topic>Energy resolution</topic><topic>Nickel</topic><topic>Proteins</topic><topic>Sensor arrays</topic><topic>Synchrotron radiation</topic><topic>Throughput</topic><topic>X-ray detectors</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Iwanczyk, J.S.</creatorcontrib><creatorcontrib>Dorri, N.</creatorcontrib><creatorcontrib>Wang, M.</creatorcontrib><creatorcontrib>Szczebiot, R.W.</creatorcontrib><creatorcontrib>Dabrowski, A.J.</creatorcontrib><creatorcontrib>Hedman, B.</creatorcontrib><creatorcontrib>Hodgson, K.O.</creatorcontrib><creatorcontrib>Patt, B.E.</creatorcontrib><collection>CrossRef</collection><jtitle>IEEE transactions on nuclear science</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Iwanczyk, J.S.</au><au>Dorri, N.</au><au>Wang, M.</au><au>Szczebiot, R.W.</au><au>Dabrowski, A.J.</au><au>Hedman, B.</au><au>Hodgson, K.O.</au><au>Patt, B.E.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>20-element HgI/sub 2/ energy dispersive X-ray array detector system</atitle><jtitle>IEEE transactions on nuclear science</jtitle><stitle>TNS</stitle><date>1992-10</date><risdate>1992</risdate><volume>39</volume><issue>5</issue><spage>1275</spage><epage>1280</epage><pages>1275-1280</pages><issn>0018-9499</issn><eissn>1558-1578</eissn><coden>IETNAE</coden><abstract>Recent progress in the development of HgI/sub 2/ energy dispersive X-ray detector arrays and associated miniaturized processing electronics for synchrotron radiation research applications is described. The experimental results with a 20-element array detector were obtained under realistic synchrotron beam conditions at SSRL. An energy resolution of 250 eV at 5.9 keV was achieved. Energy resolution and throughput measurements versus input count rate and energy of the incoming radiation have been measured. Extended X-ray absorption fine structure spectra were taken from diluted samples simulating proteins with nickel.< ></abstract><pub>IEEE</pub><doi>10.1109/23.173190</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext_linktorsrc |
identifier | ISSN: 0018-9499 |
ispartof | IEEE transactions on nuclear science, 1992-10, Vol.39 (5), p.1275-1280 |
issn | 0018-9499 1558-1578 |
language | eng |
recordid | cdi_ieee_primary_173190 |
source | IEEE Electronic Library Online |
subjects | Dispersion Electromagnetic wave absorption Energy measurement Energy resolution Nickel Proteins Sensor arrays Synchrotron radiation Throughput X-ray detectors |
title | 20-element HgI/sub 2/ energy dispersive X-ray array detector system |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T06%3A37%3A42IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_RIE&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=20-element%20HgI/sub%202/%20energy%20dispersive%20X-ray%20array%20detector%20system&rft.jtitle=IEEE%20transactions%20on%20nuclear%20science&rft.au=Iwanczyk,%20J.S.&rft.date=1992-10&rft.volume=39&rft.issue=5&rft.spage=1275&rft.epage=1280&rft.pages=1275-1280&rft.issn=0018-9499&rft.eissn=1558-1578&rft.coden=IETNAE&rft_id=info:doi/10.1109/23.173190&rft_dat=%3Ccrossref_RIE%3E10_1109_23_173190%3C/crossref_RIE%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ieee_id=173190&rfr_iscdi=true |