The optimization of high frequency operated transformers for resonant converters
In this paper the influence of the winding layout of high frequency operated transformers on the core losses and also on the leakage inductance is investigated and verified by measurements. A method of summation is used which is based on an integral equation for the magnetization and based on these...
Gespeichert in:
Hauptverfasser: | , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this paper the influence of the winding layout of high frequency operated transformers on the core losses and also on the leakage inductance is investigated and verified by measurements. A method of summation is used which is based on an integral equation for the magnetization and based on these results, some design guidelines are derived in order to optimize these components |
---|---|