Conceptual Design of the PANDA Magnet System
A magnet system comprising a 2 T superconducting solenoid for a target spectrometer and a large aperture dipole magnet for a forward spectrometer is being developed for the PANDA experiment at GSI. The inner radius of the solenoid coil is 1.1 m. The solenoid is of a split type to provide a warm bore...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on applied superconductivity 2006-06, Vol.16 (2), p.469-472 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A magnet system comprising a 2 T superconducting solenoid for a target spectrometer and a large aperture dipole magnet for a forward spectrometer is being developed for the PANDA experiment at GSI. The inner radius of the solenoid coil is 1.1 m. The solenoid is of a split type to provide a warm bore between the coil parts for the target. An energy of 23 MJ is stored in the magnet. The Dipole Magnet will provide a bending momentum of 2 Tmiddotm. The magnet is of the "H-type" with a water-cooled winding. The paper covers magnetic field and forces calculations as well as strength analysis and description of the magnet system components and their implementation |
---|---|
ISSN: | 1051-8223 1558-2515 |
DOI: | 10.1109/TASC.2005.869643 |