Investigation of electrical parameters in compact fluorescent lamps

This paper investigate characteristics of frequency, light efficiency, voltage-ampere relationship in /spl Phi/=11.8mm and /spl Phi/=16mm two kinds tube diameter compact fluorescent lamp. The aim of this paper was to investigate how to choose operating condition in different diameter lamps and how t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Lu Dilai, Zhong Lanxiang, Geoiges Zissis, Lu Zhiguo
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper investigate characteristics of frequency, light efficiency, voltage-ampere relationship in /spl Phi/=11.8mm and /spl Phi/=16mm two kinds tube diameter compact fluorescent lamp. The aim of this paper was to investigate how to choose operating condition in different diameter lamps and how to choose ballast parameters. The experimental results show the working frequency from 15 kHz to 40 kHz fit to slim and rough tube lamp both, the max light efficiency of slim tube lamp decreases faster than rough one when operating frequency below 10 kHz.
ISSN:0197-2618
2576-702X
DOI:10.1109/IAS.2005.1518787