On radio interference filter measurement

A new measurement method for on site testing of multiport radio interference filters (RIF) on shielded chamber is designed. The method is based on scalar measurement only and makes possible a pessimistic estimate of the filters damping in frequency band from DC-3 GHz. More than 120 dB dynamic of mea...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Hoffmann, K., Skvor, Z.
Format: Buchkapitel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A new measurement method for on site testing of multiport radio interference filters (RIF) on shielded chamber is designed. The method is based on scalar measurement only and makes possible a pessimistic estimate of the filters damping in frequency band from DC-3 GHz. More than 120 dB dynamic of measurement can be expected. At the time being there is no acceptable standard for these multiport measurements.