Ellipsoid models for human and guinea pigs exposed to magnetic fields

Dosimetry is necessary to scale exposures across species to compare biological responses. The functionally equivalent exposure of a human is estimated from animal exposure by dosimetry. Induced electric fields and current densities were calculated for 50 Hz, 10 G, 20 G and 30 G magnetic fields expos...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Canseven, A.G., Seyhan, N.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Dosimetry is necessary to scale exposures across species to compare biological responses. The functionally equivalent exposure of a human is estimated from animal exposure by dosimetry. Induced electric fields and current densities were calculated for 50 Hz, 10 G, 20 G and 30 G magnetic fields exposures using ellipsoid models representing human standing and guinea pig on all four feet on the ground. E fields induced by 10 G, 20 G and 30 G fields of 50 Hz were calculated as 4.04 mV/m, 8.07 mV/m and 12.11 mV/m respectively for guinea pigs. For the human model these fields were found 12.5 mV/m, 25 mV/m and 37.7 mV/m. Induced current densities were calculated between 0.404 mA/m/sup 2/ and 1.211 mA/m/sup 2/ for guinea pig, between 1.25 mA/m/sup 2/ and 3.77 mA/m/sup 2/ for human by taking the conductivity 0.1 S/m. Average value of human: guinea pig ratios (scaling factor - SF) was calculated as 3.1. The functionally equivalent exposure of human was obtained from SF of 3.1 and found between 3.23 G and 9.68 G.
DOI:10.1109/ICSMC2.2003.1429140