On the sensitivity of corrosion and fatigue damage detection using guided ultrasonic waves

Constant, long-time monitoring of large plate-like structures, e.g., oil storage tanks, can be performed using permanently attached remote sensors. A guided ultrasonic wave array consisting of piezoelectric transducer elements for the excitation and reception of the first antisymmetric Lamb wave mod...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Fromme, P., Lowe, M.J.S., Cawley, P., Wilcox, P.D.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Constant, long-time monitoring of large plate-like structures, e.g., oil storage tanks, can be performed using permanently attached remote sensors. A guided ultrasonic wave array consisting of piezoelectric transducer elements for the excitation and reception of the first antisymmetric Lamb wave mode A0, has been designed and built. Laboratory measurements for a steel plate containing various defects have been performed. The results are compared to theoretical predictions and the sensitivity of the array device for defect detection is ascertained.
ISSN:1051-0117
DOI:10.1109/ULTSYM.2004.1418002