Zero-crossing distortion in grid-connected PV inverters
Zero-crossing distortion has been observed in the ac output current produced by some grid-connected photovoltaic inverters and this can cause a resonant response between the grid impedance and the inverter filter capacitor. In some cases, particularly with large numbers of parallel-connected inverte...
Gespeichert in:
Veröffentlicht in: | IEEE transactions on industrial electronics (1982) 2005-04, Vol.52 (2), p.558-565 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Zero-crossing distortion has been observed in the ac output current produced by some grid-connected photovoltaic inverters and this can cause a resonant response between the grid impedance and the inverter filter capacitor. In some cases, particularly with large numbers of parallel-connected inverters and with weak grids, the resonance can cause voltage distortion that may be large enough to disturb other nearby equipment. A number of commercially available inverters were tested to investigate the mechanisms of this distortion. A model was then developed to allow further simulations with different numbers of inverters and varying levels of distortion to be performed. |
---|---|
ISSN: | 0278-0046 1557-9948 |
DOI: | 10.1109/TIE.2005.844254 |