Bi-directional three-phase rectifier with high-frequency isolation and power factor correction

This paper analyzes an isolated bi-directional three-phase rectifier with power factor correction, based on the matrix converter topology. The proposed converter consists of a bi-directional three-phase to one phase cycloconverter or reduced matrix converter and a bi-directional active rectifier, bo...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Garcia-Gil, R., Espi, J.M., Sanchis-Kilders, E., Ejea, J.B.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper analyzes an isolated bi-directional three-phase rectifier with power factor correction, based on the matrix converter topology. The proposed converter consists of a bi-directional three-phase to one phase cycloconverter or reduced matrix converter and a bi-directional active rectifier, both implemented by four-quadrant switches (4QSWs). Safe commutation of all the 4QSWs is implemented and incorporated in the soft-switching process. Adding a saturable inductor in series with the leakage inductance reduces switching losses. Experimental results of a 1.2 kW, /spl plusmn/15 A and 20 kHz switching-frequency prototype with an all-digital control are presented.
ISSN:0275-9306
2377-6617