Bi-directional three-phase rectifier with high-frequency isolation and power factor correction
This paper analyzes an isolated bi-directional three-phase rectifier with power factor correction, based on the matrix converter topology. The proposed converter consists of a bi-directional three-phase to one phase cycloconverter or reduced matrix converter and a bi-directional active rectifier, bo...
Gespeichert in:
Hauptverfasser: | , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper analyzes an isolated bi-directional three-phase rectifier with power factor correction, based on the matrix converter topology. The proposed converter consists of a bi-directional three-phase to one phase cycloconverter or reduced matrix converter and a bi-directional active rectifier, both implemented by four-quadrant switches (4QSWs). Safe commutation of all the 4QSWs is implemented and incorporated in the soft-switching process. Adding a saturable inductor in series with the leakage inductance reduces switching losses. Experimental results of a 1.2 kW, /spl plusmn/15 A and 20 kHz switching-frequency prototype with an all-digital control are presented. |
---|---|
ISSN: | 0275-9306 2377-6617 |
DOI: | 10.1109/PESC.2004.1355289 |