Supply voltage fluctuation characteristics of leakage transformer type operating circuit with by-pass circuit for a metal halide lamp

In this study, a by-pass circuit is provided to the secondary winding of the leakage transformer type operating circuit with by-pass circuit for a metal halide lamp. This study intends to demonstrate by simulations and experiments that content of higher harmonic components of the supply current wave...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Miyake, H., Iemura, M.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this study, a by-pass circuit is provided to the secondary winding of the leakage transformer type operating circuit with by-pass circuit for a metal halide lamp. This study intends to demonstrate by simulations and experiments that content of higher harmonic components of the supply current waveform can be controlled to the lower level by a by-pass circuit. It is also shown by this study that content of higher harmonic components of the supply current is not affected significantly by fluctuation as much as input terminal voltage /spl plusmn/10 V and can be controlled to the lower level.
ISSN:0197-2618
2576-702X
DOI:10.1109/IAS.2004.1348478