Measurement of high frequency impedance of ITER CS Model Coil and the simulation analysis of internal resonance phenomenon

This paper describes the internal resonance phenomenon of a large scale superconducting coil. The frequency dependence of electric impedance defined at the coil terminal and the voltage distribution of the layer winding were measured at the ITER CS model coil under the superconducting state in advan...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on applied superconductivity 2004-06, Vol.14 (2), p.1414-1417
Hauptverfasser: Matsukawa, M., Miura, Y.M., Shimada, K., Terakado, T., Okano, J., Isono, T., Nunoya, Y.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper describes the internal resonance phenomenon of a large scale superconducting coil. The frequency dependence of electric impedance defined at the coil terminal and the voltage distribution of the layer winding were measured at the ITER CS model coil under the superconducting state in advance of the pulse operation test. As a result, large change of the impedance and unbalance of the layer voltage were observed. The AC circuit analysis was carried out in order to evaluate the measurement results and to calculate the voltage of layer insulator. It was concluded that the higher voltage, which may appear on the layer insulation, is about a half of the coil terminal voltage in high frequency.
ISSN:1051-8223
1558-2515
DOI:10.1109/TASC.2004.830630