Tuning of a synchronously pumped optical parametric oscillator via a four-plate birefringent filter
In this paper we present a detailed discussion of the birefringent filter design strategy and the experimental performance characteristics obtained for a PPLN synchronously pumped OPO operating with birefringent filter tuning in the 1.3 -1.9 /spl mu/m region, with pulse duration of /spl sim/4 ps. We...
Gespeichert in:
Hauptverfasser: | , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this paper we present a detailed discussion of the birefringent filter design strategy and the experimental performance characteristics obtained for a PPLN synchronously pumped OPO operating with birefringent filter tuning in the 1.3 -1.9 /spl mu/m region, with pulse duration of /spl sim/4 ps. We have adopted a four-plate birefringent filter design in order to strongly suppress the subsidiary maxima, with plate thicknesses of 1.5 mm, 3 mm, 6 mm, and 12 mm. The transmission characteristics of this four-plate birefringent filter design were calculated to model the height of the subsidiary maxima and their dependence on the birefringent filter rotation angle. |
---|---|