Compression of three-dimensional medical image data based on JPEG 2000
We evaluate a compression scheme that exploits inter-slice redundancy in medical imaging that is compatible with the JPEG 2000 core coding system extensions (part 2). The scheme consists of applying a decorrelating transform in the cross-slice vertical direction subsequently compressing each slice w...
Gespeichert in:
Hauptverfasser: | , , , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We evaluate a compression scheme that exploits inter-slice redundancy in medical imaging that is compatible with the JPEG 2000 core coding system extensions (part 2). The scheme consists of applying a decorrelating transform in the cross-slice vertical direction subsequently compressing each slice with a core part 1 JPEG 2000 coder. The rates for each slice are chosen according to a heuristic log-based allocation algorithm. Two transforms were considered, the KLT and the DWT 9/spl times/7. A gain of up to 4-4 dB in RMSE was achieved using the DWT 9/spl times/7 over a baseline JPEG 2000 system that uses no decorrelating transform. |
---|---|
ISSN: | 1063-7125 |