Interval methods for certification of the kinematic calibration of parallel robots

In this paper, we demonstrate how methods based on interval arithmetic and interval analysis can be used to achieve numerical certification of the kinematic calibration of a parallel robots. We introduce our work by describing the usual calibration methods and the motivations for a numerical certifi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Daney, D., Papegay, Y., Neumaier, A.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this paper, we demonstrate how methods based on interval arithmetic and interval analysis can be used to achieve numerical certification of the kinematic calibration of a parallel robots. We introduce our work by describing the usual calibration methods and the motivations for a numerical certification. Then, we briefly present the interval methods we used and the kinematic calibration problem. In the main part, we develop our certified approach of this problem in the case of a Gough platform, and we show with numerical examples how this approach avoids wrong solutions produced by classical approach. Details on implementation and performance are also given.
ISSN:1050-4729
2577-087X
DOI:10.1109/ROBOT.2004.1308103