New oxide-trap extraction method for irradiated MOSFET devices at high frequencies
This paper proposes a new extraction method of radiation-induced oxide-trap density (/spl Delta/N/sub ot/), called OTCP (Oxide-Trap based on Charge-Pumping). In this method, we use a High Frequency (HF) standard CP measurement. We avoid the border-trap effect in CP current (I/sub cp/) measurements....
Gespeichert in:
Hauptverfasser: | , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This paper proposes a new extraction method of radiation-induced oxide-trap density (/spl Delta/N/sub ot/), called OTCP (Oxide-Trap based on Charge-Pumping). In this method, we use a High Frequency (HF) standard CP measurement. We avoid the border-trap effect in CP current (I/sub cp/) measurements. Hence, I/sub cp/ is only due to the interface-trap contribution. We demonstrate that /spl Delta/N/sub ot/ is only dependent on /spl Delta/V/sub th/ (threshold voltage shift) and /spl Delta/I/sub cpm/ (augmentation of maximum CP current). We also show that /spl Delta/V/sub th/ can be obtained from lateral shift of CP Elliot curves and /spl Delta/I/sub cpm/ from vertical shift. |
---|---|
DOI: | 10.1109/ICM.2003.237971 |