Concurrent detection of power supply noise

We propose a methodology for the concurrent detection of power supply noise affecting a general synchronous system and exceeding a tolerance bound to be chosen according to the system's constraints. Our solution is based on a suitable self-checking scheme which concurrently monitors a signal of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on reliability 2003-12, Vol.52 (4), p.469-475
Hauptverfasser: Metra, C., Schiano, L., Favalli, M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We propose a methodology for the concurrent detection of power supply noise affecting a general synchronous system and exceeding a tolerance bound to be chosen according to the system's constraints. Our solution is based on a suitable self-checking scheme which concurrently monitors a signal of the system clock distribution network and which is, by design, able to provide an output error message upon the occurrence of power supply noise. The produced error indication can then be exploited to recover from the detected noise (thus guaranteeing system's correct operation), or to accomplish diagnosis. Our scheme negligibly impacts system's performance, features self-checking ability with respect to a wide set of possible internal faults and keeps on revealing concurrently the occurrence of power supply noise, despite the possible presence of noise affecting also ground.
ISSN:0018-9529
1558-1721
DOI:10.1109/TR.2003.821937