Automation of the pulsed diagnostics process for the linear induction accelerator LIA 0.4/6
We considered solutions for soft hardware which automates the process of the pulsed microwave radiation characteristics and LIA parameter measurements. We include spectral diagnostic facilities for radiation based on reconfigurable narrow-band waveguide filter; specialized video input card obtained...
Gespeichert in:
1. Verfasser: | |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We considered solutions for soft hardware which automates the process of the pulsed microwave radiation characteristics and LIA parameter measurements. We include spectral diagnostic facilities for radiation based on reconfigurable narrow-band waveguide filter; specialized video input card obtained from the speed oscillograph (6 LOR-04 M); synchronization and guidance controller; suite and drivers for the interaction of the equipment with the PC for the control of the experimental installation operation and digital processing of the obtained signals. |
---|---|
DOI: | 10.1109/SPCMTT.2002.1213710 |