Prototype Design of Readout Electronics for the Multiple Sampling Ionization Chamber at HIAF - HFRS

Nuclear physics using radioactive beams has been the most dynamic research area in nuclear science. A High Intensity Heavy-Ion Accelerator Facility (HIAF) is currently under construction, which includes the installation of a cuttingedge High Energy Fragment Separator (HFRS) with high energy and inte...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on nuclear science 2024-09, p.1-1
Hauptverfasser: Yang, Haibo, Liu, Chengcheng, Tang, Shuwen, Lu, Fenhua, Liao, Shun, Li, Xianqin, Zhu, Jieyu, Su, Yangzhou, Zhang, Honglin, Xie, Haoqing, Quan, Hao, Sun, Xin, Wang, Longjie, Zhao, Chengxin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Nuclear physics using radioactive beams has been the most dynamic research area in nuclear science. A High Intensity Heavy-Ion Accelerator Facility (HIAF) is currently under construction, which includes the installation of a cuttingedge High Energy Fragment Separator (HFRS) with high energy and intensity capabilities. The HFRS uses the magnetic-rigidity-time-of-flight-energy-loss (Bρ-TOF-ΔE) method, which has been commonly used in nuclear fragmentation secondary beam devices to achieve high magnetic rigidity, large ion-optical acceptance, and excellent particle identification. The energy loss (ΔE) detector plays a crucial role in particle identification. The energy loss detector is designed using the multiple sampling ionization chamber (MUSIC) detector. It can significantly improve the energy resolution of the gas ionization chamber through multiple samplings. The prototype of the readout electronics of one MUSIC consists of eight charge-sensitive preamplifiers (CSPs) modules and one readout control electronics (RCE) module. The CSPs placed inside the MUSIC read the MUSIC charge signals. A RCE has eight signal input channels. The RCE receives voltage signal pulses from the CSPs, amplifies, filters, and digitizes the signal. The measured data is packed and transferred to the data acquisition (DAQ) system via a 10-Gb ethernet protocol. The readout electronics have been tested. The test results indicate that the noise performance is better than 0.22 mV (i.e., the root mean square (RMS) error), and the nonlinearity of the entire readout electronics is less than 0.17%. The joint test results of the MUSIC detector show that it has an excellent performance in measuring the radioactive source and heavy-ion beams. This paper will discuss the design and performance of the readout electronics.
ISSN:0018-9499
1558-1578
DOI:10.1109/TNS.2024.3460062