Arc voltage analysis for vacuum state estimation in vacuum interrupters
In this paper the arc voltage of a vacuum interrupter, switching a 10 A DC current, is evaluated. Voltage peaks are counted during 6 ms and represented in histograms. These histograms are unambiguously discriminative for pressures above 3*10/sup -2/ Pa. Beyond this pressure a sharp change in the per...
Gespeichert in:
Hauptverfasser: | , , |
---|---|
Format: | Tagungsbericht |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In this paper the arc voltage of a vacuum interrupter, switching a 10 A DC current, is evaluated. Voltage peaks are counted during 6 ms and represented in histograms. These histograms are unambiguously discriminative for pressures above 3*10/sup -2/ Pa. Beyond this pressure a sharp change in the performance of the arc voltage is visible. |
---|---|
DOI: | 10.1109/ISDEIV.2002.1027404 |