Loop heat pipe (LHP) development by utilizing coherent porous silicon (CPS) wicks

This paper introduces a theoretical model for a Loop Heat Pipe (LHP) utilizing a coherent porous silicon (CPS) wick. The paper investigates the effects of different parameters on the performance of the LHP such as evaporator temperature, condenser temperature, total mass charge, wick thickness, poro...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Hamdan, M., Cytrynowicz, D., Medis, P., Shuja, A., Gerner, F.M., Henderson, H.T., Golliher, E., Mellott, K., Moore, C.
Format: Tagungsbericht
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper introduces a theoretical model for a Loop Heat Pipe (LHP) utilizing a coherent porous silicon (CPS) wick. The paper investigates the effects of different parameters on the performance of the LHP such as evaporator temperature, condenser temperature, total mass charge, wick thickness, porosity, and pore size. A LHP is a two-phase device with extremely high effective thermal conductivity that uses capillary forces developed inside its wicked evaporator to pump a working fluid through a closed loop. The loop heat pipe is developed to efficiently transport heat that is generated by a highly localized concentrated heat source and then to discharge this heat to a convenient sink. This device is urgently needed to cool electronic components, especially in space applications. The LHP has been modeled utilizing the conservation equations and thermodynamic cycle. The loop heat pipe cycle is presented on a T-s diagram. A direct relation is developed between the ratio of heat going for evaporation as well as heat leaking to the compensation chamber.
ISSN:1089-9870
DOI:10.1109/ITHERM.2002.1012492