Tibial Stress Reaction in Runners
Medial tibial pain in runners has traditionally been di agnosed as either a shin splint syndrome or as a stress fracture. Our work using magnetic resonance imaging suggests that a progression of injury can be identified, starting with periosteal edema, then progressive mar row involvement, and ultim...
Gespeichert in:
Veröffentlicht in: | The American journal of sports medicine 1995-07, Vol.23 (4), p.472 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng ; jpn |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Medial tibial pain in runners has traditionally been di agnosed as either a shin splint syndrome or as a stress fracture.
Our work using magnetic resonance imaging suggests that a progression of injury can be identified, starting with periosteal
edema, then progressive mar row involvement, and ultimately frank cortical stress fracture. Fourteen runners, with a total
of 18 sympto matic legs, were evaluated and, within 10 days, referred for radiographs, a technetium bone scan, and a mag netic
resonance imaging scan. In 14 of the 18 symp tomatic legs, magnetic resonance imaging findings cor related with an established
technetium bone scan grading system and more precisely defined the ana tomic location and extent of injury. We identified
clinical symptoms, such as pain with daily ambulation and physical examination findings, including localized tibial tenderness
and pain with direct or indirect percussion, that correlated with more severe tibial stress injuries. When clinically warranted,
we recommend magnetic resonance imaging over bone scan for grading of tibial stress lesions in runners. Magnetic resonance
imaging is more accurate in correlating the degree of bone in volvement with clinical symptoms, allowing for more ac curate
recommendations for rehabilitation and return to impact activity. Additional advantages of magnetic reso nance imaging include
lack of exposure to ionizing ra diation and significantly less imaging time than three- phase bone scintigraphy. |
---|---|