Whole-Blood Glucose Testing at Alternate Sites

Whole-Blood Glucose Testing at Alternate Sites Glucose values and hematocrit of capillary blood drawn from fingertip and forearm J. Paul Lock , MD 1 , Ete Z. Szuts , PHD 2 , Kenneth J. Malomo , BS 2 and Althea Anagnostopoulos , MS 2 1 Department of Medicine, University of Massachusetts/Memorial Hosp...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Diabetes care 2002-02, Vol.25 (2), p.337-341
Hauptverfasser: Lock, J. Paul, Szuts, Ete Z., Malomo, Kenneth J., Anagnostopoulos, Althea
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Whole-Blood Glucose Testing at Alternate Sites Glucose values and hematocrit of capillary blood drawn from fingertip and forearm J. Paul Lock , MD 1 , Ete Z. Szuts , PHD 2 , Kenneth J. Malomo , BS 2 and Althea Anagnostopoulos , MS 2 1 Department of Medicine, University of Massachusetts/Memorial Hospital, Worcester, Massachusetts 2 Research Department, Abbott Laboratories, MediSense Products, Bedford, Massachusetts Abstract OBJECTIVE —To measure hematocrit (Hct) and glucose concentration in capillary blood drawn from the fingertip and forearm of a group of 50 nonfasting subjects with diabetes. RESEARCH DESIGN AND METHODS —Hct was determined indirectly by measuring Hb with the HemoCue B-Hemoglobin Photometer. Glucose was assayed with the HemoCue B-Glucose Analyzer, chosen as the independent control assay, and the Sof-Tact Blood Glucose System. Testing session with each subject lasted ∼30 min and consisted of a sequence of tests with each device (SofTact, HemoCue Glucose, and HemoCue Hemoglobin), performed on the arm and then on the fingertip. This sequence was performed three times, so all tests were done in triplicate. Additional fingersticks were performed on each subject at the start and end of the session to measure net change of glucose status during the experiment with a YSI Glucose Analyzer. The mean of the triplicate assays was used to calculate each subject’s percent of glucose difference between arm and finger [(arm glucose − finger glucose)/finger glucose]. Because of the order in which replicates were performed, time-dependent changes in the glucose status of subjects had little effect on the mean values. Thus, the percent of glucose difference calculated herein reflects the intrinsic difference between forearm and fingertip. RESULTS —Hb concentration and Hct were found to be significantly higher in the arm than in the finger. When intraperson differences were calculated, the difference for Hb and Hct was found to be 1.8 ± 1.1 g/dl (mean ± SD) and 5.3 ± 3.0%, respectively. In contrast to Hb, the percent of glucose difference between arm and finger was statistically insignificant. When measured with HemoCue, the percent of glucose difference was −0.1 ± 8% for all 50 subjects, −1 ± 6% for 20 subjects, for whom blood glucose varied 18 mg/dl. Thus, irrespective of how much blood glucose changed among the subjects, the glucose difference between forearm and fin
ISSN:0149-5992
1935-5548
DOI:10.2337/diacare.25.2.337