Delayed Processing of Blood Samples Influences Time to Positivity of Blood Cultures and Results of Gram Stain-Acridine Orange Leukocyte Cytospin Test

We investigated in vitro whether storage of blood samples influences the time to positivity used for the calculation of the differential time to positivity (DTP) and the results of the Gram stain-acridine orange leukocyte Cytospin (AOLC) test. A 24-hour storage of blood samples at room temperature m...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of Clinical Microbiology 2007-08, Vol.45 (8), p.2691-2694
Hauptverfasser: Schwetz, I, Hinrichs, G, Reisinger, E.C, Krejs, G.J, Olschewski, H, Krause, R
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We investigated in vitro whether storage of blood samples influences the time to positivity used for the calculation of the differential time to positivity (DTP) and the results of the Gram stain-acridine orange leukocyte Cytospin (AOLC) test. A 24-hour storage of blood samples at room temperature may lead to false-negative DTP and false-positive Gram stain-AOLC test results, whereas storage at 4°C does not.
ISSN:0095-1137
1098-660X
DOI:10.1128/JCM.00085-07