Automated liver volumetry in orthotopic liver transplantation using multiphase acquisitions on MDCT
The aim of this study was to test a new automated hepatic volumetry technique by comparing the accuracies and postprocessing times of manual and automated liver volume segmentation methods in a patient population undergoing orthotopic liver transplantation so that liver volume could be determined on...
Gespeichert in:
Veröffentlicht in: | American journal of roentgenology (1976) 2012-06, Vol.198 (6), p.W568-W574 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The aim of this study was to test a new automated hepatic volumetry technique by comparing the accuracies and postprocessing times of manual and automated liver volume segmentation methods in a patient population undergoing orthotopic liver transplantation so that liver volume could be determined on pathology as the standard of reference.
Both manual and automated multiphase MDCT-based volume measurements were strongly correlated to liver volume (Pearson correlation coefficient, r = 0.87 [p < 0.0001] and 0.90 [p < 0.0001], respectively). Automated multiphase segmentation was significantly more rapid than manual segmentation (mean time, 16 ± 5 [SD] and 86 ± 3 seconds, respectively; p = 0.01). Overall, automated liver volumetry based on multiphase CT acquisitions is feasible and more rapid than manual segmentation. |
---|---|
ISSN: | 0361-803X 1546-3141 |
DOI: | 10.2214/AJR.11.7468 |