Accurate time measurements with plastic scintillation counters

A plastic scintillation counter, with a useful areaof 24×25 cm 2 and a resolution of 290 ps (fwhm) for determining the time of impact of a minimum ionizing particle, is described. The resolution may be brought down to 100 ps with smaller counters. Lower time spreads are obtained with more ionizing p...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nuclear instruments & methods 1978-01, Vol.153 (2), p.409-412
Hauptverfasser: Binon, F., Bricman, C., Duteil, P., Gouanère, M., Jansen, J., Lagnaux, J.P., Peigneux, J.P., Sillou, D., Spighel, M., Stroot, J.P., Vilain, P.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A plastic scintillation counter, with a useful areaof 24×25 cm 2 and a resolution of 290 ps (fwhm) for determining the time of impact of a minimum ionizing particle, is described. The resolution may be brought down to 100 ps with smaller counters. Lower time spreads are obtained with more ionizing particles.
ISSN:0029-554X